15
Chapter 4
Specifications
All specifications are subject to change without notice.
Typical for 25°C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Relay specifications
Table 1. Relay specifications
Contact rating (resistive load)
Between open contacts: 750 VAC, 50/60 Hz, 1 min.
Between coil and contacts: 1500 VAC, 50/60 Hz, 1 min.
10 to 55 Hz (dual amplitude 1.5 mm)
100 M ohms min. (500 V @ 1 minute)
Mechanical: 10 ^7 mechanical operations, min.
Electrical: 100,000 min at full load
Isolated inputs
Table 2. Isolated input specifications
Non-polarized, opto-isolated (Not TTL compatible)
Time constant: 5 ms (200 Hz)
Filter control: Each input individually switch selectable
Power-up /reset: Filters off
Power consumption
Table 3. Power consumption specifications
All relays off: 0.2 A typical
All relays on: 1.2 A typical
Commenti su questo manuale