B-20 Configuring DASYLab for Daq Devices 989593 DASYLab – Standard Driver
General Experiment Setup
The Experiment Setup regulates the general operation of the programmable hardware. These parameters
affect the underlying performance of the A/D block at run-time.
To open the dialog box, select “Experiment Experiment Setup.” Note that you can also open the
dialog box by clicking on the A/D icon in the toolbar.
Experiment Setup Window
There are five sections in the Experiment Setup window. Of these, only
Global Settings and Driver Settings are used with IOtech hardware.
Global Settings
Sampling Rate – determines how fast the scans will be read
Block Size – determines how incoming data will be processed
Synchronization – sets the method of regulating system pacing
Sampling Rates
Device
Time Between Channel Scans
DaqLab Devices
DaqScan Devices
DaqBoard/1000 and /2000 Series
DaqBook/2000 Series
5 µs, 10 µs, or 1000 µs
Daq ISA-Type Devices 10 µs
TempBook 10 µs
WaveBook 1 µs