12
The watchdog timer period is set via a jumper. The default position of 30 seconds is shown above. Table 6-1
below describes the W/D timer settings as well as the other header pins.
Table 6-1. Watch Dog Timer Settings
Pin Description
1 30 S timeout when jumpered to Pin2
2 See above
3 10 second timeout when jumpered to Pin 4
4 See above
5 1 second timeout when jumpered to pin 6
6 See above
7 Alarm_Out/n (TTL)
8PC +5V
9 Alarm_Out (open collector up to +12V)
10 Alarm _Out 5K pullup TO 5V when jumpered to
pin 9
11 SPDT Relay Common
12 SPDT Relay Normally Open
13 No Connection
14 SPDT Relay Normally Closed
15 No Connection
16 No Connection
6.4
EXAMPLE PROGRAMS
Example programs written in C/C++, Visual Basic (v5.0 and later), and Delphi (v3.0 and later) are included with
the Satellite Monitor. They demonstrate how to use each of the API functions provided by the Satellite Library.
These examples are installed in the subdirectories C, VB, and Delphi of the installation directory.