DAQFlex Message-based Firmware Specification Analog output calibration messages
17
AIRES
Get the resolution of the A/D used for calibrating the D/A.
The first character in the value returned indicates that the value is signed.
AISLOPE
Get the slope for the current AICAL:RANGE setting.
"AOCAL{ch}:AISLOPE=0xhex value"
The analog output channel.
The slope currently set for AICAL:RANGE.
"AOCAL{0}:AISLOPE=0x14B525A3"
The hex value is used to preserve the precision of the double precision floating point
value.
AIVALUE
Get the value of the analog input channel being calibrated.
"AOCAL{ch}:AIVALUE=value"
The AI channel being calibrated.
The AI channel value in counts.
When this message is sent, the device switches the internal CalConfig to the DAC
channel that is specified in the message.
LOCK
Lock the AOCAL component.
The device returns INVALID if any AOCAL property message is accessed while the
AOCAL component is locked.
Commenti su questo manuale