IEEE Bus Handshaking
4.6 DATA LINES
The
GPIB
provides eight data lines for a bit parallel/byte serial data transfer. These
eight data lines use the convention of
DIO1
through
DIO8
instead of the binary
designation of
D0
to
D7
. The data lines are bidirectional and are active low.
4.7 MULTILINE COMMANDS
Multiline
(bus) commands are sent by the
Active
Controller
over the data bus with
ATN
asserted. These commands include addressing commands for talk, listen, Untalk
and Unlisten.
4.7.1 Go To Local (GTL)
This command allows the selected devices to be manually controlled. ($01)
4.7.2 Listen Address Group (LAG)
There are 31 (0 to 30) listen addresses associated with this group. The 3 most
significant bits of the data bus are set to 001 while the 5 least significant bits are the
address of the device being told to listen.
4.7.3 Unlisten (UNL)