READ
On read the most significant A/D byte is read.
The A/D Bits code corresponds to the voltage on the input according to Table 4-3.
Table 3-3. A/D Bit Codes
0 Volts
Full Scale
00
½ Full Scale0 Volts8002048
+Full Scale+ Full ScaleFFF4095
UNIPOLARBIPOLARHEXDECIMAL
WRITE
Writing to this register starts a 12-bit A/D conversion.
Note: Place several NO-OP instructions between consecutive 12-bit A/D conversions
to avoid over-running the A/D converter.
3.3 STATUS AND CONTROL REGISTER
BASE ADDRESS + 2
This register address is two registers, one is read active and one is write active.
READ = STATUS
MUX0MUX1MUX2IRQIP1IP2IP3EOC
01234567
EOC = 1 the A/D is busy converting and data should not be read.
EOC = 0 the A/D is not busy and data may be read.
IP3 to IP1 are the digital input lines.
IRQ is the status of an edge triggered latch connected to the “Interrupt Req” pin on
the analog connector. It is high (1) when a positive edge has been detected. It may
be reset to 0 by writing to the INTE mask at BASE + 2 write.
MUX 2 to MUX 0 is the current multiplexer channel. The current channel is a
binary coded number between 0 and 7 .
WRITE = CONTROL
MUX0MUX1MUX2INTEOP1OP2OP3OP4
01234567
OP4 to OP1 are the digital output lines.
10