PCI-DAS6023 and PCI-DAS6025 User's Guide Specifications
32
Table 3. Absolute accuracy components - all values are (±)
Averaged Noise +
Quantization (mV)
1
Absolute Accuracy
at FS (mV)
1
Averaged measurements assume dithering and averaging of 100 single-channel readings.
Table 4. Differential non-linearity specifications
System throughput
Table 5. System throughput specifications
1. 1. Single channel, single input range.
2. 2. Multiple channel, single input range
3. 3. Single channel, multiple input
ranges.
Default to value for cbAInScan() range
Note 1: For conditions 1-2 above, specified accuracy is maintained at rated throughput. Condition 3
applies a calibration coefficient which corresponds to the range value selected in cbAInScan().
This coefficient remains unchanged throughout the scan. Increased settling times may occur
during gain-switching operations.
Settling time
Settling time is defined here as the time required for a channel to settle to within a specified accuracy in
response to a full-scale (FS) step. Two channels are scanned at a specified rate. A –FS DC signal is presented to
channel 1; a +FS DC signal is presented to channel 0.
Table 6. Settling time specifications