Measurement-computing PCM-DAC08 Manuale Utente Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 23
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
DIO0DIO1DIO2DIO3DIO4DIO5DIO6DIO7
01234567
BASE + 4 - Interrupt Control & Digital I/O Direction Control
WRITE: Set control bits.
READ: Read status of control bits.
LDIRUDIRINT_ENINTREQXXXX
01234567
INTREQ
Default is no interrupt has occurred = 0. When set to 1 an interrupt has occurred.
External interrupts, when enabled, occur at TTL high (2.5<TTL High<5V).
A read base+1 clears this bit.
Interrupt status routinues may want to read and verify this bit then clear it with a read
of Base +1.
INT_EN
Enable external interrupt. Enable = 1. Disable = 0.
17