CB-7080 & CB-7080D Counter/Timer User's Guide $AA4
2-20
$AA4
Description: Read the status of digital filter. Refer to "Digital filter setting" for more information.
Syntax: $AA4[chk](cr)
$ A delimiter character
AA 2-character HEX module address, from 00 to FF
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Response:
Valid response !AAS[chk](cr)
Invalid response ?AA[chk](cr)
no response Syntax error, communication error or address error
! A delimiter character indicating a valid response
? A delimiter character indicating an invalid response
AA 2-character HEX module address
S=0 digital filter is disabled
S= 1 digital filter is enable
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Examples:
Digital filter is disabled:
command: $014(cr)
response: !010(cr)
Digital filter is enabled:
command: $024(cr)
response: !021(cr)