Measurement-computing DBK Part 2 Manuale Utente Pagina 194

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 306
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 193
DBK100/D is terminated in a Deutsch connector, enabling watertight connections to a mating connector
with up to 14 thermocouples. Custom pin-configurations are available to match with existing mating
connectors. Inside the Deutsch connector [tethered to the DBK100/D] is the cold junction sensor, which is
measured by the system and used to calculate the TC reading. The pinout follows.
Female Pin
(Looking at back side of Deutsch)
Male Pin
(Looking at back side of Deutsch)
P1 Signal P1 Signal P1 Signal
* f CH 6 LO * a CH 3 HI * t CJC+
R CH 13 LO B CH 10 HI * s CJC-
* g CH 6 HI * k CH 2 LO
S CH 13 HI C CH 9 LO
* h CH 5 LO * m CH 2 HI
T CH 12 LO D CH 9 HI
* i CH 5 HI * n CH 1 LO
U CH 12 HI E CH 8 LO
* j CH 4 LO * p CH 1 HI
V CH 11 LO F CH 8 HI
* x CH 4 HI * q CH 0 LO
W CH 11 HI * b CH 7 LO
* z CH 3 LO * r CH 0 HI
A CH 10 LO
* c CH 7 HI
NOTE!
Do not make connections to
pins t and s! Do not short
pins t and s! Pins t and s are
connected internally to Cold
Junction Compensation!
* Asterisk denoted lowercase letter.
pg. 6, DBK100 Series 907994 DBK Option Cards and Modules
Vedere la pagina 193
1 2 ... 189 190 191 192 193 194 195 196 197 198 199 ... 305 306

Commenti su questo manuale

Nessun commento