DBK44, pg. 8 877095 DBK Option Cards and Modules
DBK44 – Specifications
Name/Function: 2-Channel 5B Signal Conditioning Card
Module Capacity: 2 “input only” 5B modules
Weight: 0.25 kg (8 oz.) with no modules installed
Cable (optional): CA-37-x
DC Input Fuse: 4 A
Connections:
Male DB37 mates via CA-37-1 cable with P1 on the LogBook,
DaqBook, ISA-type DaqBoard*, or Daq PC-Card.
User connections include 8 screw-terminals (4 per channel).
Screw terminations, per channel, are: +EXC, +Vin, -Vin, -EXC
Isolation to Primary Acquisition Device (LogBook or Daq Device):
Input Power: 0 VDC
Signal Inputs: 1500 VDC
Input Channel-to-Channel: 500 VDC
Environmental:
Operating Temperature: 0 to 50°C
Humidity: 0 to 80% RH @ 30°C; de-rate 3%/°C
Altitude: 0 to 2000 m
*Note: For DaqBoard/2000 Series and /2000c Series boards, the use of a
DBK200 Series P4-to-P1 adapter is required.