USB-SSR08 User's Guide Functional Details
External power connectors
The USB-SSR08 has two external power connectors labeled POWER IN and POWER OUT on the enclosure.
The
POWER IN connector is labeled PWR IN on the board, and the POWER OUT connector is labeled PWR
OUT
on the board.
Connect the
POWER IN connector to the supplied +9 V external power supply. External power is required to
operate the USB-SSR08. The
POWER OUT connector lets you power additional daisy chained MCC USB
Series products from a single external power supply. Depending on your load requirements, daisy chained
products may require a separate power supply. Refer to "Power limitations using multiple USB-SSR08 devices
"
on page 3-4 for more information.
USB LED
The USB LED indicates the communication status of the USB-SSR08. This LED uses up to 5 mA of current
and cannot be disabled. explains the function of the USB LED. Table 3-2
Table 3-2. USB LED Illumination
LED Illumination Indication
Steady green The USB-SSR08 is connected to a computer or external USB hub.
Pulsing green
Initial communication is established between the USB-SSR08 and the computer, or data is being
transferred.
PWR LED
The USB-SSR08 incorporates an on-board voltage supervisory circuit that monitors the external 9 V power. If
the input voltage falls outside of the specified ranges the
PWR LED shuts off. Tab explains the function of
the PWR LED.
le 3-3
Table 3-3. PWR LED Illumination
PWR LED
illumination
Indication
Steady green External power is supplied to the USB-SSR08.
Off
Power is not supplied by the external power supply, or a power fault has occurred. A power fault
occurs when the input power falls outside of the specified voltage range of the external supply
(6.0 V to 12.5 V).
I/O module type switch (S1)
Switch S1 is a four-position switch that sets the type of each module group for input or output (default). You
cannot mix input and output modules within a group. You can use InstaCal to read the current I/O type
configuration for each module group. shows switch S1 configured with its default settings. Figure 3-2
Figure 3-2. Switch S1 default configuration
CH
CL
OUTIN
S1
3-2