USER’S MANUAL DaqBook/2000 Series and DaqOEM/2000 Series 16-Bit, 200 kHz Multifunction Data Acquisition Systems DaqBook/2001DaqBook/2005DaqBook/202
Step 4 - Configure Computer Network Settings Note: We recommend that you discuss this procedure with your Network Administrator before proceeding. 1.
Daq Systems 1 Daq Systems, the Modular Concept …… 1-1 DaqBooks, DaqBoards, and Daq PC-Cards ….. 1-2 Using DBK Cards and Modules for Signal Conditio
1-2 Daq Systems 958795 DaqBook/2000 Series and DaqOEM/2000 Series DaqView and DASYLab can only be used with one DaqBook/2000 Series, DaqOEM S
DaqBook/2000 Series and DaqOEM/2000 Series 958795 Daq Systems 1-3 Daq Data Acquisition Devices Category Device Description DaqBook/2000 Series
1-4 Daq Systems 958795 DaqBook/2000 Series and DaqOEM/2000 Series Using DBK Cards and Modules for Signal Conditioning The DBK signal-cond
Daq Software The Daq devices have software options capable of handling most applications. Three types of software are available: • ready-to-use gra
1-6 Daq Systems 958795 DaqBook/2000 Series and DaqOEM/2000 Series
DaqBook/2000 Series and DaqOEM/2000 Series 2 Device Overviews I/O Comparison Matrix …… 2-1 Overview …… 2-2 Product Features …… 2
2-2 Device Overviews 898095 DaqBook/2000 Series and DaqOEM/2000 Series Overview DaqBook/2020, /2001, /2005, DaqOEM/2001, and DaqOEM/2005 are
Triggering DaqBook/2020, /2001, /2005, DaqOEM/2001, and DaqOEM/2005 each support a full complement of trigger modes including: • Hardware analog trig
ii
2-4 Device Overviews 898095 DaqBook/2000 Series and DaqOEM/2000 Series Digital Input Channels The devices allow for either synchronous scannin
DaqBook/2000 Series and DaqOEM/2000 Series 898095 Device Overviews 2-5 Asynchronous I/O Operations The DaqBook/2000 Series and DaqOEM/2000 Ser
2-6 Device Overviews 898095 DaqBook/2000 Series and DaqOEM/2000 Series Synchronous Operation Matrix The following table applies to DaqBook/20
DaqBook/2001 & DaqOEM/2001 16 Analog Input via P1 4 Analog Output via P3 40 Digital I/O via P2 & P3 4 Counter In 2 Timer Out via P3 Su
2-8 Device Overviews 898095 DaqBook/2000 Series and DaqOEM/2000 Series DaqBook/2005 & DaqOEM/2005 16 Analog Input via P1 No DAC Chann
DaqBook/2000 Series and DaqOEM/2000 Series 898095 Device Overviews 2-9 DaqBook/2020’s on-board scan sequencer lets you select up to 16384 channe
2-10 Device Overviews 898095 DaqBook/2000 Series and DaqOEM/2000 Series
Block Diagrams 3 DaqBook/2001, DaqOEM/2001, DaqBook/2005, & DaqOEM/2005 …… 3-1 DaqBook/2020 …… 3-2 Detail “TC” (Thermocouple Input Circuitry) f
3-2 Block Diagrams 966895 DaqBook/2000 Series and DaqOEM/2000 Series DaqBook/2020 Block Diagram DaqBook/2020 Block Diagram
Detail “TC” (Thermocouple Input Circuitry) for DaqBook/2020 Detail “V” (Differential Voltage Input Circuitry) for DaqBook/2020 DaqBook/2000 Ser
Warranty Information Contact Measurement Computing by phone, fax, or e-mail in regard to warranty-related issues: Phone: (508) 946-5100, fax: (508) 9
3-4 Block Diagrams 966895 DaqBook/2000 Series and DaqOEM/2000 Series
Connectors, Indicators, Cables, & Pinouts 4 DaqBook/2020 …… 4-1 DaqBook/2001 and DaqBook/2005 …… 4-3 DaqOEM/2001 and Daq
Rear Panel The DaqBook/2020 rear panel contains P1 and P2 DB37 connectors, a MAC Address Label, DIN5 power connector, power switch, 2 Synchronizatio
DaqBook/2001 and DaqBook/2005 DaqBook/2001 and /2005 provide for up to 256 channels of analog input expansion. They have 40 built-in digital I/O cha
POWER Switch: A rocker-type switch with a “0” label for Power Off, and a “1” for Power On. POWER IN: +10 to +30 VDC, through a socket type DIN5 conne
Cables Should you need help in regard to cables or have any other product inquiries please contact the factory. Cables for use with DaqBook/2000 Ser
4-6 Connectors, Indicators, Cables, & Pinouts 898095 DaqBook/2000 Series and DaqOEM/2000 Series
Pinouts P1 and JP1 – Analog I/O …… 4-8 P2 and JP2 – Digital I/O …… 4-9 P3 and JP3 – Pulse/Frequency/Digital I/O (Does not apply to DaqBook/2020E)…
P1 and JP1 Analog I/O P1, DB37 Connector for DaqBook/2000 Series Devices JP1,
P2 and JP2 Digital I/O P2, DB37 Connector
iv 898695 DaqBook/2000 Series and DaqOEM/2000 Series Your order was carefully inspected prior to shipment. When you receive your system, car
P3 and JP3 Pulse/Frequency/Digital I/O JP3, 40-pin header for DaqOEM/2000
DaqBook/2000 and DaqOEM/2000 Series User’s Manual 959295 Software 5-1 Software 5 Overview …… 5-1 Out-of-the-BoxTM Software …… 5-1 Drivers for Th
5-2 Software 959295 DaqBook/2000 and DaqOEM/2000 Series User’s Manual Reference Notes: ¾ The software document modules, DaqView, DaqViewXL, an
Configuring the System for Operation 6 Step 1 - Install the Software ….. 6-2 Step 2 - Determine the type of Network C
CAUTION Turn off power to the system devices and externally connected equipment before connecting cables. Electric shock or damage to equipment c
Dedicated Network - with a direct cable connection from the PC to the device In this scenario a DaqBook/2020 is connected directly to an Ethernet jack
LAN with a DHCP Server (Local Area Network with a Dynamic Host Configuration Protocol server) Many corporations use the LAN/Server with DHCP arrang
STEP 3 – Connect the System Components Reference Note: For information regarding connections, refer to Chapter 4, Connectors, Indicators, Cables,
STEP 4 – Power-up the System What you will need: A power supply with a range of +10 VDC to +30 VDC. The power supply needs to have a male DIN5 co
STEP 5 – Configure the Computer’s Network Settings [Applies to “dedicated networks” only] If using a LAN (Local Area Network), which has a DHCP s
DaqBook/2000 Series and DaqOEM/2000 Series 898695 v PDF 457-0905 DBK Options.pdf The DBK Option Ca
Local Area Connection Properties 5. Double-click the “Internet Protocol (TCP/IP)” component (previous figure). The “Internet Protocol (TCP/IP) Pro
Configure the Computer’s TCP/IP settings as follows. Internet Protocol (TCP/IP) Properties 6. Select the “Use the following IP Address” radio
STEP 6 – Configure Device Network Settings using DaqIPConfig Applies only to a LAN (Local Area Network), which has a no DHCP server. If using a LA
STEP 7 – Configure and test the System using the Daq* Configuration Applet The Daq* Configuration applet, designed for 32-bit Windows NT/2000/XP s
3. Set the properties of the first-level device. In this step you will set the device properties according to one of the following two methods, depe
4. Test the system connections. a. Make sure the device has been properly installed and is powered-on. b. Make sure all cables are properly and s
Reference Notes: Depending on your application and system setup, related information can be found in the following sources: ¾ The DBK Options Manu
CE Compliance & Noise Considerations 7 Overview ……7-1 CE Standards and Directives …… 7-1 Safety Conditions ……7-2 Emissions/Immunity Conditions
For clarification, terms used in some Declarations of Conformity include: • pollution degree: any addition of foreign matter, solid, liquid or gaseo
CE Enhancements for DBKs The following CE enhancements are detailed in the DBK Cards and Modules User’s Manual (p/n 457-0905). • DBK41/CE • Edge G
vi 898695 DaqBook/2000 Series and DaqOEM/2000 Series This page is intentionally blank.
Noise Considerations Controlling electrical noise is imperative because it can present problems even with the best measurement equipment. Most labora
Ethernet CE Kit Installation Instructions Introduction The Ethernet CE Kit includes three ferrite clamp-on inductive collars
Install the Ferrite Inductive Collars 1. Place one ferrite collar at each end of the Ethernet cable. Snap the two collars shut. See photos. 2.
Taking Measurements 8 Introduction …… 8-1 Scanning …… 8-1 Triggering …… 8-2 Synchronous I/O Operations…… 8-3 Asynchronous I/O Operations …… 8-7 Usi
8-2 Taking Measurements 898695 DaqBook/2000 and DaqOEM/2000 Series Triggering Triggering can be the most critical aspect of acquiring data. Da
Pre- and Post-Triggering Modes. Six modes of pre- and post-triggering are supported, providing a wide variety of options to accommodate any measuremen
8-4 Taking Measurements 898695 DaqBook/2000 and DaqOEM/2000 Series Synchronization Model for DaqBook/2000 and DaqOEM/2000 Series Devices, D
SYNC Notes: • When a DaqBook is programmed as a synchronization slave, the TTL trigger source is automatically derived from the SYNC port. • Whe
8-6 Taking Measurements 898695 DaqBook/2000 and DaqOEM/2000 Series Digital I/O Channels There are 24 Digital I/O channels available to DaqBook
DaqBook/2000 and DaqOEM/2000 Series 898695 Taking Measurements 8-7 Asynchronous I/O Operations Each DaqBook allows asynchronous input of an
DaqBook/2000 Series and DaqOEM/2000 Series 999895 vii Table of Contents Quick Start 1 – Daq Systems 2 – DaqBook/2000 Series and DaqOEM/2000 Series
8-8 Taking Measurements 898695 DaqBook/2000 and DaqOEM/2000 Series Counter Input Channels (CTR0, CTR1, CTR2, CTR3) DaqBooks and DaqOEMs have
DaqBook/2000 and DaqOEM/2000 Series 959095 Calibration 9-1 Calibration
9-2 Calibration 959095 DaqBook/2000 and DaqOEM/2000 Series
Troubleshooting and Customer Support 10 Electrostatic Discharge (ESD), Handling Notice…… 10-1 Product Care …… 10-1 ReadMe Files and the Install CD-
10-2 Troubleshooting & Customer Support 897995 DaqBook/2000 and DaqOEM/2000 - IO version ReadMe Files and the Install CD-ROM The Install CD-R
DaqBook/2000 and DaqOEM/2000 Series – IO version 897995 Troubleshooting & Customer Support 10-3 Ethernet Problems • • • • • Make sure the
10-4 Troubleshooting & Customer Support 897995 DaqBook/2000 and DaqOEM/2000 - IO version Frequently Asked Questions (1) Topic: Environment
DaqBook/2000 and DaqOEM/2000 Series – IO version 897995 Troubleshooting & Customer Support 10-5 Customer Support If you want to Expand or
10-6 Troubleshooting & Customer Support 897995 DaqBook/2000 and DaqOEM/2000 - IO version
DaqBook/2000 and DaqOEM/2000 Series 899595 Specifications 11-1 Specifications 11 DaqBook/2020, /2001, /2005, DaqOEM/2001, and DaqOEM/200
viii 999895 DaqBook/2000 Series and DaqOEM/2000 Series This page is intentionally blank.
Specifications are subject to change without notice. 11-2 Specifications 958893 DaqBook/2000 and DaqOEM/2000 User’s Manual Settling Time: 5 µ
Specifications are subject to change without notice. DaqBook/2000 and DaqOEM/2000 Series 898695 Specifications 11-3 Thermocouple Input Specif
Specifications are subject to change without notice. 11-4 Specifications 898695 DaqBook/2000 and DaqOEM/2000 User’s Manual Input Sequencer Ana
Specifications are subject to change without notice. DaqBook/2000 and DaqOEM/2000 Series 898695 Specifications 11-5 5. Counter/Totalizer Trig
Specifications are subject to change without notice. 11-6 Specifications 898695 DaqBook/2000 and DaqOEM/2000 User’s Manual Frequency/Pulse Cou
Specifications are subject to change without notice. DaqBook/2000 and DaqOEM/2000 Series 898695 Specifications 11-7 Accessories and Cables
Specifications are subject to change without notice. 11-8 Specifications 898695 DaqBook/2000 and DaqOEM/2000 User’s Manual Manuals Manual S
Glossary 959395 G-1 Glossary Acquisition A collection of scans acquired at a specified rate as controlled by the sequencer. Analog A signal of va
G-2 959395 Glossary Digital-to-Analog Converter (DAC) A circuit or device that converts digital values (binary bits), into
Glossary 959395 G-3 Trigger An event to start a scan or mark an instant during an acquisition. The event can be defined in various ways; e.g., a TTL
1121-0940, rev 1.0 324631A-01 Printed in Hungary DaqBook & DaqOEM
G-4 959395 Glossary
Commenti su questo manuale