19
Chapter 5
Specifications
All specifications are subject to change without notice.
Typical for 25 °C unless otherwise specified.
All specifications apply to all temperature and voltage input channels unless otherwise specified.
Specifications in italic text are guaranteed by design.
Analog input
Table 1. Generic analog input specifications
AD42_321
Dual 24-bit Sigma-Delta
4 differential, 4 single-ended
Temperature input; T0x toT3x
500 VDC minimum between field wiring and USB
interface
Temperature input.
Software programmable to match sensor type
Factory default configuration is Disabled mode.
Once configured, each channel reverts to the mode
previously set by the user.
Vx_H inputs are connected directly to their screw
terminal pins.
Vx_L inputs are disconnected from their screw
terminal pins and internally connected to GND.
Vx_H and Vx_L inputs are connected directly to
their screw terminal pins.
Tx_H and Tx_L inputs are connected directly to
their screw terminal pins.
Semiconductor sensor; T0x toT3x
±10 V, ±5 V, ±2.5 V, ±1.25 V; software selectable
Absolute maximum input
voltage
T0x to T3x relative to GND
(pins 9, 19, 22, 27, 30, 33, 36, 39, 49)
±25 V max (power on)
±40 V max (power off)
V0x to V3x relative to GND
(pins 9, 19, 22, 27, 30, 33, 36, 39, 49)
±25 V max (power on)
±15 V max (power off)
5 GΩ (power on)
1 MΩ (power off)
10 GΩ (power on)
2.49 kΩ (power off)
T0x to T3x, with open thermocouple
detect disabled.
T0x to T3x, with open thermocouple
detect enabled.