4-6 Installing the DynaRes
11-09-01
DataShuttle and DynaRes
Base Address Settings
Possible DynaRes Base Address Settings
Value Switch Positions*
1 2 3 4
Comments
300H U U U U Factory setting
310H D U U U -
320H U D U U May interfere with hard disk drive
330H D D U U -
340H U U D U Recommended alternative
350H D U D U -
360H U D D U -
370H D D D U May interfere with parallel printer
380H U U U D -
390H D U U D -
3A0H U D U D -
3B0H D D U D -
3C0H U U D D -
3D0H D U D D May interfere with graphics adaptor
3E0H U D D D -
3F0H D D D D May interfere with floppy disk drive
* U = Up D = Down
Changing Hardware Interrupts
For users of Windows programs that employ hardware interrupts, the DynaRes board provides for changing
the interrupt number, if necessary.
Refer to page 4 2 to locate the interrupt jumper block on the DynaRes board. By repositioning the jumper,
which is a plug, to another socket on the block, you can select another of these interrupts: IRQ2, IRQ5,
IRQ7, IRQ11, IRQ12, or IRQ15. (Remember that on AT computers the IRQ2 selection is actually the IRQ9
line.)