44
CB-7000 DIO Manual
2.15 @AA(Data)
Description: Set Digital Output
Command: @AA(Data)[CHK](cr)
@ Delimiter character
AA Address of setting module (00 to FF)
(Data) output value, the data format is following:
(Data) is one character for output channel less than 4
For CB-7060/60D, from 0 to F
For CB-7063/63D/63A/63AD/63B/63BD, from 0 to 7
(Data) is two characters for output channel less than 8
For CB-7044/44D/50/50D, from 00 to FF
For CB-7065/65D/65A/65AD/65B/65BD, from 00 to 1F
For CB-7066/66D/67/67D, from 00 to 7F
(Data) is four characters for output channel less than 16
For CB-7042/42D, from 0000 to 1FFF
For CB-7043/43D, from 0000 to FFFF
Response: Valid Command: >[CHK](cr)
Invalid Command: ?[CHK](cr)
Ignore Command: 
Syntax or communication error may get no response.
> Delimiter for valid Command.
? Delimiter for invalid Command.
! Delimiter for ignore Command. The module is in Host
Watchdog Timeout Mode, and the output is set to SafeValue.
Example:
Command: @017 Receive: >