CB-7000 DIO Manual
2.18 ~AA0
Description: Read Module Status
Command: ~AA0[CHK](cr)
~ Delimiter character
AA Address of reading module (00 to FF)
0 Command for read module status
Response: Valid Command: !AASS[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax or communication error may get no response.
! Delimiter for valid Command
? Delimiter for invalid Command
AA Address of response module(00 to FF)
SS Module status, 00=host watchdog timeout status is clear,
04=host watchdog timeout status is set. The status will store
into EEPROM and only may reset by the Command ~AA1.
Example:
Refer to Sec. 2.21, ~AA3EVV example.
Related Command:
Sec. 2.17, ~**; Sec. 2.19, ~AA1; Sec. 2.20, ~AA2; Sec. 2.21,
~AA3EVV; Sec. 2.22, ~AA4V; Sec. 2.23, ~AA5V
Related Topic:
Sec. 3.2, Module Status; Sec. 3.3, Dual Watchdog Operation