Measurement-computing CB-COM-7021 Manuale Utente Pagina 34

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 76
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 33
34
CB-7021, CB-7022, CB-7024 Users Manual
2.6 ~AAO(Data)
Description: Set Module Name
Syntax: ~AAO(Data)[CHK](cr)
~ Delimiter character
AA Address of setting module (00 to FF)
O Command for setting module name
(Data) New name for module, max 6 characters
Response: Valid Command: !AA[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no
response.
! Delimiter for valid command
? Delimiter for invalid command
AA Address of response module (00 to FF)
Example:
Command: ~01O7021 Receive: !01
Set address 01 module name to 7021, returns successfulful.
Command: $01M Receive: !017021
Read address 01 module name, returns 7021.
Related Command:
Sec. 2.5 $AAM